Your tenant is configured for SSPR as shown in the exhibit. None of the users hold a Microsoft Entra administrator role. Each user goes to https://aka.ms/sspr, enters their user ID and passes the CAPTCHA.
| SSPR setting | Value |
|---|---|
| Self service password reset enabled | Selected (group: SSPR-Pilot) |
| Number of methods required to reset | 2 |
| Methods available to users | Mobile app code, Email, Security questions |
| Password writeback | Not configured |
| User | Member of SSPR-Pilot | Identity source | Registered methods |
|---|---|---|---|
| Amira | Yes | Cloud-only | Mobile app code, Email |
| Ben | No | Cloud-only | Mobile app code, Email |
| Chen | Yes | Cloud-only | |
| Dana | Yes | Synchronized from on-premises AD DS by using password hash synchronization | Email, Security questions |
Match each user to how the SSPR portal handles their reset request.
- Correct match: Allowed to proceed with a reset that requires verification using two methods.
Amira is in the pilot group, has a cloud-managed password and has registered two allowed methods, so the eligibility checks pass.
- Correct match: Told to contact an administrator because SSPR is not enabled for the account.
SSPR is scoped to SSPR-Pilot and Ben isn't a member, so the scope check fails.
- Correct match: Told to contact an administrator because too few authentication methods are registered.
The policy requires two methods and Chen has registered only one, so the authentication-method check fails.
- Correct match: Told to contact an administrator because the password is managed on-premises without writeback.
Dana's password is managed on-premises, so password writeback is required for an SSPR reset.
Microsoft Entra ID checks SSPR scope, registered authentication methods and where the password is managed. Amira passes these checks and can proceed using two methods; Ben fails the scope check, Chen lacks a second method, and Dana requires password writeback. A failed eligibility check directs the user to an administrator rather than registration during the reset. The configured method count does not permit verification using only one method.